nuova marea ltd
  • HOME
  • SOFTWARE
    • Free UDP tools
    • Pytheas
    • CamControl
    • FHL Wind Logger
    • MaxSea >
      • Time Zero Navigator
      • Time Zero Explorer
      • Time Zero ECS
      • Time Zero Plot
      • Mediterranean Charts CMAP
      • Mediterranean Charts Navionics
  • NMEA INTERFACES
    • Certificates >
      • IEC60945
      • ABS Certificate
      • ABS Certificate of Design Assessment
      • Greek Flag approval
    • NM-251 Series >
      • NM251A
      • NM251A-MUX
      • NM251B
      • NM251D-BRC
      • NM251D-ZDA
      • NM251D-DTM
    • NMEA Buffers >
      • NM251A
    • NMEA Multiplexers >
      • NM251MUX
      • NM541MUX
    • Ethernet NMEA products >
      • NM422ETH
      • NM541MUX
    • NMEA to Furuno AD-10
    • Discrete series
    • NMEA Inclinometers
    • Call Alarms
    • Chain Counters
    • Custom products
  • BLOG
  • SUPPORT
  • SEARCH
  • FORUM
  • CONTACT
  • MARINE TRAFFIC
NM-422ETH    
NMEA-0183 Multiplier With Ethernet Interface       (User Guide)
 
Introduction, Operation, Inputs, Outputs, Power supply, Connections, Connecting Ethernet interface, Led indicators, Configuring as Dual Converter, AutoPilot port, Specifications, troubleshooting, Installing Discovery utility, Using Discovery utility, DHCP Configuration, Manual Configuration, Virtual Port,  UDP configuration, Downloads
Order - Quotation request
Picture
Price 270.00 Euro
On-line orders -15%
Specifications


Specifications


Supply Voltage

10 to 35 Volt DC

Power supply protection

PTC Resettable Fuse

Vmax: 60V, Imax: 40A, Ihold: 0,25A (23°C),

Itrip:0,5A (23°C), Max time to trip (23°C): 2,2 sec for 1,25A

Current Consumption

50mA in idle state/ 150mA in full output mode

Inputs

2 x NMEA-0183, optically isolated

Common Mode Rejection: 10kV/usec

Isolation: 480 Vrms

Input Resistance

1,5 KOhm

Outputs

4 x buffered RS-422/TTL (general purpose)

1 x RS-232

1 x TCP/IP interface

1 x TTL received from charting system through

RS232 for

navigational purposes (e.g. autopilot control)

Output protection

Buffered for all RS-422 outputs

Baud Rate NMEA inputs

4.800 Baud

4.800/8/N/1 for RS-232

Baud Rate NMEA outputs

4.800 Baud for buffered outputs

4.800/8/N/1 for RS-232

Indicators

Power on

Most Significant Input (Ina)

Less Significant Input (Inb)

Data transmission (TXD)

Data reception (RXD)

Network cable connected

TCP/IP data flow

Dimensions

Width = 110mm/134,80 mm

Depth = 82 mm

Height = 43 mm

Housing

Styrene


Basic Hardware troubleshooting

No LED indications and the power LED off.
- Check Power Supply voltage levels and connection polarity
- If correct check fuse located inside the enclosure
- Else call service

Power LED is on but no transmission is achieved
- Check if instrument is transmitting data
- If yes check listener’s port polarity
- Else call service

Charting system sends through RS-232 or Ethernet interface data to autopilot and there is no reception from my autopilot.
- Check configuration of the physical or virtual serial port of the computer to follow the 4.800/8/N/1 standards
- Check if signal from the autopilot port is correctly applied to the autopilot
- Else call service